Case Study Electrical Faults Connection Looseness
When monitoring the condition of rotating equipment, one of the easily overlooked problems is electrical connection looseness. The Artesis e-MCM has detected the loose wire connections on an ID Fan at a wood mill in the USA. e-MCM monitoring software captured this problem automatically and displayed it as an increase on the external electrical connection bar chart. Upon the correction of the problem, the loose wiring trend fell back to normal level.